Pengaruh Waktu Kontak dan Debit Aliran Proses Penyisihan Fe dan Mn pada Air Limbah Elektroplating Menggunakan Cascade Aerator

Authors

  • Ragiel Ramadhan Universitas Riau

DOI:

https://doi.org/10.31258/jptl.2.2.105-114

Keywords:

Cascade aerator, waktu kontak, debit aliran, besi, mangan

Abstract

Electroplating wastewater contains high levels of Fe and Mn. One of the treatment methods to remove Fe and Mn in electroplating wastewater is the aeration method using a cascade aerator. the aeration method using a cascade aerator. Aeration is the process of adding oxygen to the water so that it can cause oxidation reactions of Fe and Mn, which will form precipitates. and Mn, which will form Fe(OH)3 and MnO2 precipitates. The gas transfer coefficient (KLa) value during the aeration process was then determined. The Fe and Mn levels before the aeration process were 9.84 mg/L and 4.78 mg/L, respectively. obtained the highest decrease in Fe levels at 240 minutes with a flow rate of 90 mL/s with an efficiency of 70.63% and the highest decrease in Mn levels occurred contact time of 300 minutes with a flow rate of 90 mL/s with an efficiency of 62.76%. 62,76%. The highest gas transfer coefficient (KLa) value occurred at a contact time of 300 minutes with a flow rate of 90 mL/s of 0.0975 KLa/min. The research results obtained have met the quality standards of wastewater according to the Regulation of the Minister of Environment No. 5 of 2014 on Wastewater Quality Standards

References

Abuzar, S.S., Yogi, D.P., dan Reza, E.E. (2012). Koefisien Transfer Gas (KLa) Pada Proses Aerasi Menggunakan Tray Aerator Bertingkat 5 (Lima). Jurnal Teknik Lingkungan UNAND, 9 (2), 155-163.

Bennefield, L.D dan Randall, C.W. (1980). Biological Process Design for Wastewater Treatment, Prentice-Hall, Inc, Englewwod Cliffs, NJ 07632

Harimu, L., dkk. (2020). Perbandingan Kemampuan Aerasi Sembur (Spray) dengan Metode Adsorpsi Menggunakan Adsorben Serbuk Kulit Buah Kakao untuk Menurunkan Kadar Besi dan Mangan Pada Air Sumur Gali. Indonesian Journal of Chemical Research, 8(2):137-143.

Karuniawan, H.dan Ali, M. (2021). Variasi Tray Aerator Dengan Penambahan Media Kaolin Dan Karbon Aktif Untuk Menurunkan (Fe) dan (Mn) Terlarut Di Air Sumur. EnviroUS, 1(2), 135-142.

Metcalf & Eddy Inc. (2003). Wastewater Engineering Treatment and Reuse (4th ed.). McGraw-Hill Published Companies.

Pribadi, R., Daud, S., dan Elystia, S. (2018) Penurunan Kadar Besi (Fe) pada Air Tanah dengan Menggunakan Cascade Aerator (Studi Air Tanah Universitas Riau). Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains, 5, 1-5.

Rosna, S. A. (2022) The Koefisien Transfer Gas (KLa) Cascade Aerator Berzeolit Pada Penyisihan Besi (Fe) Dari Air Gambut Terhadap Waktu Kontak dan Ukuran Partikel Zeolit: Koefisien Transfer Gas (Kla). Journal Of Environmental Management and Technology, 1(2)

S. S. Hosseini, E. Bringas, N. R. Tan, I. Ortiz, M. Ghahramani, and M. A. Alaei Shahmirzadi, (2016) “Recent progress in development of high performance polymeric membranes and materials for metal plating wastewater treatment: A review,” J. Water Process Eng., vol. 9, pp. 78–110,

Salimin, Z. dan Nurifitriyani, I. (2013). Pengolahan Limbah Industri Elektroplating Dengan Proses Koagulasi Flokulasi. Prosiding SEMIRATA 2013, 1(1)

Published

28-11-2023

How to Cite

Ramadhan, R. (2023). Pengaruh Waktu Kontak dan Debit Aliran Proses Penyisihan Fe dan Mn pada Air Limbah Elektroplating Menggunakan Cascade Aerator. JOURNAL OF ENVIRONMENTAL MANAGEMENT AND TECHNOLOGY, 2(2), 105–114. https://doi.org/10.31258/jptl.2.2.105-114